TTS_Logo

Tel 0845 3102766
Fax 0870 2869547

International Tel :00441215258070

International Fax:00441215258545

email:sales@ttstec.com

Powering your business forward

Y2 3 Phase Induction Motor
Property and Features:
  
B5 Frame without foot end shield with flange
mm
Frame No. Flange No. Poles   Overall dimension
D E F G1) M N P2) R3) S4) T Flange hole number AC AD HF L
Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Tolerance Basic size Limit deviation
63M FF115 24 11   23 ±0.260 4   8.5   115 90   140 0 ±1.5 10   ø1.0 3    0 4 130 70 130 230
+0.006     +0.013 +0.360 -0.100
71M FF130 246 14 -0.003 30 5    0 11     0 130 110 -0.009 160    0 3.5   145 80 145 255
  -0.030 -0.10      
80M FF165 2468 19   40 ±0.310 6   15.5   165 130   200 12     175 145 185 295
           
90S 24   50 8   20         195 155 195 320
           
90L +0.009     +0.014     345
-0.004     -0.011    
100L FF215 28   60 ±0.370   24   215 180   250 ±2.0 15 +0.430 ø1.5 4   215 180 245 385
     0        0  
112M   +0.036         240 190 265 400
           
132S FF265 38   80 10   33   265 230   300     275 210 315 470
           
132M             510
           
160M FF300 42   110 ±0.430 12 37   300 250   350 ±3.0 19   5   330 255 385 615
+0.018   +0.014    
160L +0.002   -0.013     670
         
180M 48   14 42.5       380 280 430 700
           0
180L       -0.120 740
      0      
200L FF350 55   16 49 -0.20 350 300 ±0.016 400     420 305 480 770
       
225S FF400 48 60   140 ±0.500 18    0 53   400 350 ±0.018 450 ±4.0     8 470 335 535 815
  -0.043      
225M 2 55   110 ±0.430 16 49     820
    +0.520  
468 60   140 ±0.500 18 53      0   845
       
250M FF500 2     500 450 ±0.020 550     510 370 595 910
+0.030    
468 65 +0.011 58    
       
280S 2         580 410 650 985
       
468 75   20    0 67.5    
  -0.052    
280M 2 65 18    0 58       1035
-0.043      
468 75   20    0 67.5      
  -0.052      
         
              1.G=D-GE and the maximum tolerance of GE is ( +0.10
0
) for frame NO.80 and is ( +0.20
0
) for other ones.
          2.P size is the maximum limit value.
          3.R is the distance from flange nating surface to axial extending shoulder.
          4.Location tolerance of S hole is based on axial line.


  
B5 Frame without foot end shield with flange
mm
Frame No. Flange No. Poles   Overall dimension
D E F G1) M N P2) R3) S4) T Flange hole number AC AD HF L
Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Whorl hole Tolerance Basic size Limit deviation
63M FT75 24 11   23 ±0.260 4   8.5   25 60   90 0 ±1.0 M5 ø0.4 2.5   4 130 70 130 230
+0.006     +0.012  
71M FT85 246 14 -0.003 30 5    0 11     0 85 70 -0.007 105 M6 ø0.5   145 80 145 255
  -0.030 -0.10    
80M FT100 2468 19   40 ±0.310 6   15.5   100 80   120 ±1.5 3.0   0 175 145 185 295
        -0.100
90S FT115 24   50 8   20   115 95   140 M8 ø1.0   195 155 195 320
         
90L +0.009     +0.013   345
-0.004    0    0 -0.009  
100L FT130 28   60 ±0.370 +0.036 24 -0.20 130 110   160 3.5   215 180 245 385
        0
112M       -0.120 240 190 265 400
         
         
              1.G=D-GE and the maximum tolerance of GE is ( +0.10
0
) for frame NO.80 and is ( +0.20
0
) for other ones.
          2.P size is the maximum limit value.
          3.R is the distance from flange nating surface to axial extending shoulder.
          4.Location tolerance of S hole is based on axial line.


  
B5 Frame without foot end shield with flange
mm
Frame No. Flange No. Poles   Overall dimension
D E F G1) M N P2) R3) S4) T Flange hole number AC AD HF L
Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Basic size Limit deviation Tolerance Basic size Limit deviation
180M FF300 2468 48   110   14 42.5   300 250     0 ±3.0 19   ø1.5 5 4 380 280 430 760
+0.018      
180L +0.002     800
       
200L FF350 55   16 49 350 300 ±0.016 400     420 305 480 840
       
225S FF400 48 60   140 ±0.500 18 53   400 350 ±0.018 450 ±4.0     8 470 335 535 905
       
225M 2 55   110 ±0.430 16    0 49     910
  -0.043    
468 60   140 ±0.500 18 53     935
         0
250M FF500 2     500 450 ±0.020 550   -0.120 510 370 595 1015
+0.030    
468 65 +0.011 58    
       
280S 2         580 410 650 1110
       
468 75   20    0 67.5    
  -0.052    
280M 2 65 18    0 58       1150
-0.043     0 +0.520  
468 75   20    0 67.5 -0.20    0  
  -0.052    
315S FF600 2 65   18   0 58 600 550 ±0.022 660 24 ø2.0 6 645 530 900 1280
  -0.043
46810 80   170 20   0 71 1510
  -0.052
315M 2 65   140 18   0 58 1310
  -0.043
46810 80   170 22   0 71 1430
  -0.052
315L 2 65   140 18   0 58 1310
  -0.043    0
46810 80   170 22   57 -0.150 1430
   
355M FF740 2 75   140 20   67.5 740 680 ±0.025 800 710 655 1010 1640
   
46810 95 +0.035 170 25   0 86 1670
+0.013 -0.052
355L 2 75 +0.030 140 20   67.5 1640
+0.011  
46810 95 +0.035 170 25   86 1670
+0.013  
         
              1.G=D-GE and the maximum tolerance of GE is ( +0.20
0
).
          2.P size is the maximum limit value.
          3.R is the distance from flange nating surface to axial extending shoulder.
          4.Location tolerance of S hole is based on axial line.